FLIR identiFINDER R 425
Next Generation Radionuclide Identification Device identiFINDER® R425
The identiFINDER® R425 is the next generation of the most deployed radionuclide identification device (RID), offering 360-degree coverage so you can locate and measure gamma and neutron radioactive sources with confidence. It builds on FLIR’s trusted algorithms with advanced heuristics and hybrid identification techniques. With the familiar identiFINDER user interface and 3-button control, you can operate the R425 quickly, communicate results, and take command of any situation, in any environment, remotely. When other systems fail in extremely high gamma fields, the identiFINDER R425 provides pinpoint accuracy and remains fully operational. The identiFINDER R425 goes the distance with balanced ergonomic design, unparalleled ruggedness, flexible power management, and usability.
The R425 provides an ideal balance of size, weight, and performance for various missions including surveying, emergency response, and environmental monitoring.
identiFINDER R425
Technology : Radionuclide identification device (RID); Gamma and Gamma/Neutron Models
Gamma Detector - Nal (TI) : 1.77 x 1.77 x 1.77 in (45 x 45 x 45 mm) cubic detector with silicon photomultiplier (SiPM)
Neutron Detector - ZnS (GN model only) : 27 x 58 x 5 mm moderated panels (2 each)
Energy Range (Gamma) : 20 keV - 3 MeV
Gamma Sensitivity (Cs-137) : 1610 cps/μSv/h
Neutron Sensitivity > 4 cps/nv
Gamma Spectrum Length : 1024 channels
Dose Rate Range (Cs-137) : 10 µrem/h – 1 rem/h ± 10%, 100 nSv/h – 10 mSv/h ± 10%
Dose Rate Range ID Mode (Cs-137) : 0.1 µrem/h – 5 mrem/h, 1 nSv/h – 50 µSv/h
Overload Dose Rate Range >1 rem/h, >10 mSv/h
Stabilization : Sourceless gain stabilization
Linearization : Real time linearization of gamma energy
Typical Resolution : ≤ 7% FWHM at 662 keV (20˚C)
Service Interval : 5-year factory maintenance
Sampling & Analysis
Sample Introduction : Absorption of EM gamma and neutron emissions
Threats : Detects neutron and gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
Nuclide Identification : According to ANSI N42.34
Library Categories : SNM, IND, MED, NORM
Time to Identification : From a few seconds to a few minutes
System Interface
Display & Alerts : 2.7” diagonal (400x240 pixels) screen; sunlight readable; visible through polarized glasses
Communications : USB-C (2x), Bluetooth (BLE 5.0)
Data Storage : 8GB internal memory
Training Requirements : <10 mins for operator; 1 hour for advanced user
Software : Onboard webserver software
Data File Format : According to ANSI N42.42
Power
Input Voltage : 100-240 AC (wall adapter and USB-C cable supplied)
Battery Specification : Internal Li-ion cells; additional user-selectable external battery (1 each 16650 Li-ion or 2 each CR123) ;hot-swappable
Cold Start Time : ≤20 seconds from cold start
Environmental
Operating Temp : -22 to 140 °F (-30 to 60 °C)
Operating Humidity : 10 to 93%, non-condensing
Storage Temperature : 14 to 95 °F (-10 to 35 °C)
Physical Features
Dimensions (L x W x H) : 9.3 x 3.9 x 3.7 in (235 x 100 x 95 mm)
Weight : ≤2.6 lbs (≤1.2 kg)
Enclosure & Protection : Injection molded housing with overmold; rating IP67 according to IEC 60529;MIL-STD 810g Salt / Fog compliant
8 other products in the same category:
preparation injection
Posijet® - Independent...
For low, medium and high energy radiopharmaceuticals
low and medium energy
Medisharp - shielded bin for...
Easy decontamination thanks to design of lead covered...
waste management
PRA3 - Shielded sharp bin
Functional: ideal for storage of used and contaminated...